TechXZone

Fujitsu SET-ARTH45KHTA-HP 12.5kW High Static Ducted System 1 Phase High Performance| Includes UTY-RNRT Controller

5/5

Fujitsu SET-ARTH45KHTA-HP 12.5kW High Static Ducted System 1 Phase High Performance| Includes UTY-RNRT Controller

Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer’s Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock – never a factory second in sight!

Shop with Confidence

Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer’s Warranty
Secure Online Payments

Description

12.5kW Cooling
15.0kW Heating
| Includes  UTY-RNRT Controller

High-Performance Range | R32

Specification

Indoor unit ARTH45KHTA
Outdoor unit AOTH45KCTA
Operation Type Reverse Cycle
Power Source
V/Ph/Hz
230 / 1 / 50
Cooling Capacity
kW (Rated (Min – Max))
12.50 (5.6 – 14.5)
Heating Capacity
kW (Rated (Min – Max))
15.00 (5.2 – 17)
Input Power Cooling
kW (Rated (Max))
3.43 (4.39)
Input Power Heating
kW (Rated (Max))
3.49 (4.46)
EER Cooling
kW/kW
3.61
COP Heating
kW/kW
4.3
Star Rating Cooling
(0-10) (Hot / Average / Cold)
3 / 3 / 3
Star Rating Heating
(0-10) (Hot / Average / Cold)
3 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.785 / 4.573 / 4.76
Heating Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.702 / 4.305 / 3.753
Total Cooling Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
5.079 / 5.18 / 5.528
Heating Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
4.693 / 4.446 / 3.992
Running Current
amps (Cooling / Heating)
15.1 / 15.3
Moisture Removal
l/hr
0.9
Indoor Sound Pressure Cooling
dBA (High / Quiet)
43 / 35
Indoor Sound Pressure Heating
dBA (High / Quiet)
43 / 35
Outdoor Sound Pressure
dBA (Cooling / Heating)
53 / 53
Outdoor Sound Power
dBA
70
Static Pressure Range
PA (Min to Max)
60 to 260
Air Circulation (Indoor – High Fan) Cooling
l/sec
903
Air Circulation (Indoor – High Fan) Heating
l/sec
903
Indoor Unit Dimensions
mm (Height x Width x Depth)
425 x 1250 x 490
Indoor Unit Weight
kg
53.00
Outdoor Unit Dimensions
mm (Height x Width x Depth)
1418 x 970 x 370
Outdoor Unit Weight
kg
95.00
Piping Connects
mm Ø (Liquid / Gas)
9.52 / 15.88
Pipe Length
m (Max (Precharged))
75 (30)
Max Height Difference
m
30
Operation Range Cooling
°CDB (Min to Max)
-10 to 50
Operation Range Heating
°CDB (Min to Max)
-15 to 24
Refrigerant Type R32
Refrigerant Amount
g
3,400

Read more