TechXZone

Mitsubishi Electric PUMY-P200YKMD-AR1 22.4 kw Outdoor Unit Only

5/5

Mitsubishi Electric PUMY-P200YKMD-AR1 22.4 kw Outdoor Unit Only

Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer’s Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock – never a factory second in sight!

Shop with Confidence

Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer’s Warranty
Secure Online Payments

Description

22.4 kW Cooling
25.0 kW Heating

Twin Fan Heat Pump VRF O/U

Specifications

SERIES PUMY-P (Twin Fan)
Model PUMY-P200YKMD
Power Source VKMD: YKMD: 1-phase 220-230-240 V, 50 Hz; 1-phase 220 3-phase 380-400-415 V, 50 Hz; 3-phase 380 V, 60 Hz V, 60 Hz
Cooling Capacity kW 22.4
(Nominal)*1 Power Input kW 6.22
Current Input A 10.16 9.65 9.30
EER kW 3.60
AEER kW 3.17
Temperature Range of Cooling Indoor W.B 15.0 ~ 24.0 C
Outdoor D.B -5.0 ~ 52.0C *4 *5
Heating Capacity kW 25.0
(Nominal)*2 Temperature Range of Heating Power Input kW 6.00
Current Input A 9.80 9.31 8.98
COP kW 4.17
ACOP Indoor kW W.B 3.78
15 ~ 27 C
Outdoor D.B -20 ~ 15 C
Indoor Unit Connectable Sound Pressure Level (measured in anechoi Total Capacity 50% to 130% of Outdoor Unit Capacity
Model/Quantity c room) dB P15-P200/12
57/61
Refrigerant Piping Diameter Liquid Pipe mm (in.) 9.52 (3/8) Flare *8
Gas Pipe mm (in.) 19.05 (3/4) Flare
Fan Type x Quantity Propeller Fan x 2
Airflow Rate m3/min 134
L/s 2,233
cfm 4,732
Control, Driving Mechanism DC Control
Motor Output kW 0.20 + 0.20
Compressor Type x Quantity Scroll Hermetic Compressor x 1
Manufacturer Mitsubishi Electric Corporation
Starting Method Inverter
Motor Output kW 5.3
External Finish External Dimension (H x W x D) mm Galvanised Steel Sheet Munsell No. 3Y 7.8/1. 1
1,338 x 1,050 x 330 (+25)
Protection Devices High Pressure Protection High Pressure Switch
Inverter Circuit (COMP./FAN) Overcurre nt Detection, Overheat Detection (Heat Sink Thermistor)
Compressor Compressor Thermistor, Overcurrent Detectio n
Fan Motor Overheating, Voltage Protection
Refrigerant Type x Original Charge R410A x 7.3kg
Control Linear Expansion Valve
Net Weight kg 138 *9
Heat Exchanger Cross Fin and Copper Tube
HIC Circuit (HIC: Heat Inter-Changer) HIC Circuit
Defrosting Method Drawing External Reversed Refrigerant Circuit
RK01J635
Wiring VG79J111
Standard Attachment Optional Parts Document Installation Manual
Accessory Ground Lead Wire x 1
Joint: CMY-Y62-G-E Header: CMY-Y64/68-G-E

Read more